Unconfigured Ad
Collapse
15 results in 0.0021 seconds.
Keywords
Members
Tags
-
Preferred analyzer for library size/library quality
Hello! I am new to the world of NGS and am curious about the preferred instrument for checking library quality. The ones that seem most popular are Agilent...
-
bioanalyzeR: New R package for data from the Agilent Bioanalyzer and TapeStation
I wrote an R package for importing electrophoresis data from the Agilent Bioanalyzer and TapeStation and graphing the results with ggplot2 or analyzing...
-
Tapestation imaging
How does the Tapestation (2200/4200) measure fluorescently stained biomolecules ?
Does it scan fluorescence in real-time (during eletrophoresis)...
-
Looking for a standardized method of library quantification and quality control
Hello all,
I am wondering if anyone out there has discovered/created a standardized method for library quantification and quality control...
-
Bioanalyzer/TapeStation fragment sizes larger than agarose gel
I am preparing libraries for GBS, and although the agarose gel image is as expected (i.e. the bulk of fragments between 200 and 400bp), TapeStation result...Last edited by cpylant; 10-27-2017, 08:56 AM.
-
Amplicon resolving differently between bioanalyzer and tapestation
Hello,
We are seeing a discrepancy between the Bioanalyzer and Tapestation for a large amplicon product that we received for sequencing. We received...Last edited by Pab77; 01-25-2016, 12:13 PM.
-
TapeStation 4200
Has anyone here tried the new Agilent's device, TapeStation 4200?
http://www.genomics.agilent.com/en/T...eStation-Instr...
-
Tapestation quality peaks show unwanted larger fragments.
Hi all,
I used Covaris to shear human genomic DNA at a set size of 300bp and 200bp respectively. This is to sequence my samples...Last edited by mzahir89; 08-19-2015, 02:20 AM.
-
Agilent TapeStation vs. Qubit: RNA concentration.
SCENARIO:
After RNA extraction (RNA-seq is my aim), I check the concentration of the extracted RNA with Qubit, and then run the extracted...
-
TapeStation 2200: multiple problems
Dear users,
this is my first post at SEQanswers. I work at a NGS core facility as scientific head, which involves a lot of troubleshooting....
-
Which is more reliable - Tapestation or Qubit?
Hi there,
I'm planning to do some miRNAseq on human FFPE tissue. I've used the Qiagen FFPE miRNA kit to extract goal RNA including miRNA....
-
Agilent TapeStation 2200?
Anyone tried one as a bioanalyzer replacement? 1-16 samples, vague but seems to load itself from strips or plates , can use partial chips. Not quite...